2020年5月30日星期六

How to Wear and Take off Disposable Medical Gloves

The beginning and development of disposable gloves is to solve the long-term need for cleaning users and protective barriers people.
Now, according to the International Journal of Health and Safety, after nitrile gloves have become a useful material in the medical field, many latex gloves production line exporters have begun to wear them. Although nitrile is more durable than latex gloves, this synthetic rubber does not (completely) replace latex. However, it is a product targeted at other market needs.
Medical making machine suppliers share with you: In modern life, the use of disposable gloves is becoming more common. Not only in medical institutions, but also in many other institutions or units, such as food processing, beauty salons, electronics factories, etc., the industry needs disposable gloves. Disposable gloves play a vital role in safety management, helping to reduce the risk of cross-infection between doctors and patients, and avoiding injuries to workers and objects. Compared to other gloves, it not only It only plays a role of safety protection, it is more hygienic.
When wearing disposable gloves every day, medical staff usually pay attention to the following points:
1. First choose gloves that fit your hand shape. If you choose gloves that are too tight or too loose. Too loose will make it difficult to hold, too tight will cause easy tearing.
2. Before putting on gloves, please prepare disposable gloves in a clean place and make sure to remove all hand jewelry and wash your hands.
3. When putting on gloves, place the glove box on a clean workbench, hold the glove's wrist with one hand, and then place it on the other hand until the glove reaches the fingertips, then place the other Keep your hands on it and avoid touching the outside of the gloves during the whole process.
However, medical personnel tend to ignore the correct steps for removing disposable gloves, which invisibly reduces the protective effect of the gloves. Therefore, in order to truly achieve the correct protective effect, medical personnel should follow the correct steps to remove disposable gloves to ensure the patient and his health.
1. Grasp the edge of the glove at the wrist of your left hand with your right thumb, index finger, and middle finger (do not touch the skin), and then pull the glove out of the inner layer and take off.
2. Knead off the left hand gloves and put them in the palm of the right hand.
3. Insert the index finger, middle finger, and ring finger of the left hand into the gloves of the right hand, and force the fingers to the outside of the body and turn them out from the inside.
4. Wrap the glove of the right hand with the glove of the palm and throw it into the trash can.
5. Wash your hands immediately after taking off your gloves.
Cast Steel Hand Moulds Base
Cast Steel Hand Moulds Base

2020年5月22日星期五

Classification, Production and Testing Requirements of Medical Gloves (Part 2)

04, Production process requirements
(I) Relevant requirements for product manufacturing
The production process of medical glove products should be specified. Key processes and special processes should be noted in the process flow chart, and their process control points should be explained. Clarify the use of various processing aids and the control of impurities (such as residual monomers and small molecule residues) in the production process.
Medical glove production line generally includes: ingredients, mold cleaning (hand mold acid and alkali cleaning, hand mold water washing, hand mold immersion in hot water), hand mold immersion coagulant, drying, dipping, drying, curl , Leaching, isolating agent / chlorine treatment, drying, demoulding, vulcanization, drying molding, primary packaging, sterilization (if any), etc. The key procedures and special processes are: leaching, chlorine treatment, vulcanization, primary packaging, sterilization (if any), etc.
The production process of single-use sterile PVC medical examination gloves generally includes: batching, filtering, defoaming, dipping, plasticizing, powdering, sorting, demoulding, packaging, etc. Key processes and special processes include: defoaming, impregnation, plasticizing, packaging, etc.
Attention should be paid to the quality control requirements of raw materials for medical gloves, and the source and quality requirements of raw materials should be clarified. The raw materials should have relatively stable production processes and sources of supply to ensure product quality. The storage of raw materials should be protected from moisture, contamination and pests, especially latex and starch must be stored in an environment that can prevent the growth of microorganisms.
Medical Glove Production Line
(2) Sterilization process requirements
The sterilization process (methods and parameters) and sterility assurance level (SAL) of medical making machine china should be specified, and a sterilization confirmation report should be provided. For the products to be sterilized by the end user, the recommended sterilization process (methods and parameters) and the basis for the recommended sterilization method should be determined. If ethylene oxide is used for sterilization, the requirements for residues and the treatment methods adopted shall be clarified, and research data shall be provided.
(Three) product expiration date
The basis for determining the validity of medical gloves and the relevant verification data should be provided. Refer to EN 455-4-2009 "Requirements and Tests for the Determination of Shelf Life of Disposable Medical Gloves". And research data to maintain the integrity of the package during the stated validity period and transport and storage conditions.
05. Product instruction and labeling requirements
Product descriptions and labels shall comply with the "Medical Device Instructions and Label Management Regulations" (Order of the State Food and Drug Administration No. 6), "Symbols for the labeling, marking and providing information of medical devices for medical devices. Part 1: General requirements" (YY / T 0466.1-2009) and related standards.
(1) The inner packaging shall be clearly marked:
(1) size;
(2) "Left" or "Right" should be marked on the inner packaging;
(3) Powdered gloves should have “Note: Aseptic operation should be used to remove surface powder before surgery to minimize the risk of adverse tissue reactions.” Or “Once the gloves have been treated with any surface powder material, there should be a warning The surface powder should be removed aseptically before surgery. "Or equivalent;
(4) Gloves made of natural rubber latex should have “(product) contains natural rubber latex that can cause allergic reactions” or equivalent instructions;
(5) If the product is declared to contain protein, the specified process limits shall be given;
(6) "Hypoallergenicity" should not be marked.
(2) Unit packaging generally includes the following:
(1) the name or trademark of the manufacturer or supplier;
(2) Materials used;
(3) "Straight fingers" or "curved fingers", or similar words indicating the content of gloves design;
(4) the words "hemp surface" or "glossy surface", "with powder" or "no powder", or similar effects on the type of gloves;
(5) size;
(6) Production batch number, production date, use period or expiration date;
(7) Indicate the product status: "sterilized unless the package is opened or damaged" or "non-sterile";
(8) "One-time use";
(9) the words "surgical gloves" or "examination gloves";
(10) For category 1 gloves, the words "Products are made of natural rubber latex that may cause allergic reactions" are marked.
(11) During storage of the product, do not touch oil, acid, alkali, copper, manganese or other organic solvents. Avoid sunlight or artificial light containing ultraviolet rays. The warehouse should be free of ozone generating devices and kept away from radioactive materials.
(Three) multi-unit packaging
Multi-unit packaging is a box of products with a predetermined number of units of gloves of the same size. The purpose is to facilitate safe transportation and storage. Multi-unit packages are labeled as single packages, and the number of gloves and additional storage instructions should be indicated.

2020年5月14日星期四

Classification, Production and Inspection Requirements of Medical Gloves (Part 1)

01. Classification and management of medical gloves
Medical gloves include sterile medical surgical gloves, medical sterile examination gloves, medical examination gloves (not supplied sterile).
Sterile medical surgical gloves, medical sterile examination gloves, management category Ⅱ, original classification code 6866, now classified code 14. Medical examination gloves provided non-sterile, management category I, original classification code 6866, now classified code 14.
Sterile medical surgical gloves are suitable for protective use during clinical surgical operations. They are worn on the hands of surgeons to prevent the spread of dandruff and bacteria to open surgical wounds and prevent the body fluids of surgical patients from being transmitted to medical personnel. The role of two-way biological protection.
Medical (sterile) examination gloves are used to check or touch the patient's condition while being worn on the doctor's hand or fingers to prevent cross-infection between the patient and the user during the medical examination and diagnostic treatment.
Medical Glove Production Line
Medical Glove Production Line
02. Structural composition of medical gloves
Medical glove production line believes that medical surgical gloves are generally made of natural rubber latex, nitrile rubber latex, neoprene latex, styrene-butadiene rubber r thermoplastic elastomer solution or emulsion, styrene-butadiene rubber emulsion and other materials.
Medical (sterile) examination gloves are generally made of natural rubber latex, nitrile rubber latex, neoprene latex, styrene-butadiene rubber or thermoplastic elastomer solution or emulsion, styrene-butadiene rubber emulsion, polyvinyl chloride, polyethylene and other materials.
Medical gloves are classified according to rubber type, design and surface type, and generally have the following forms:
Divided by rubber type: 1 type, 2 type, 3 type.
For example: rubber surgical gloves, type 1 refers to gloves made from natural rubber latex;
Type 2 is gloves made from nitrile rubber latex, neoprene latex, styrene-butadiene rubber solution or emulsion, thermoplastic elastomer solution or emulsion;
Type 3 is a glove made by mixing or compounding the materials of Type 1 and Type 2.
According to the design style, it is divided into straight type (R type) and curved type (C type).
According to the surface type, it can be divided into: hemp surface (T type), smooth surface (S type), powder (P type), powderless (F type).
03. Test items of medical gloves
(A) sterile medical surgical gloves:
Should comply with GB 7543-2006 "Single-use sterile rubber surgical gloves", GB 24787-2009 "Single-use non-sterile rubber surgical gloves", GB 24788-2009 "Limits of residual powder on the surface of medical gloves, water extraction protein" Requirements.
(2) Medical examination gloves:
Should meet the requirements of GB 10213-2006 "Single-Use Rubber Examination Gloves", GB 24786-2009 "Single-Use Polyvinyl Chloride Medical Examination Gloves", GB 24788-2009 "Limits of Residual Powder and Water Extraction Protein on the Surface of Medical Gloves" Requirements.
(2) Medical examination gloves:
Should meet the requirements of GB 10213-2006 "Single-Use Rubber Examination Gloves", GB 24786-2009 "Single-Use Polyvinyl Chloride Medical Examination Gloves", GB 24788-2009 "Limits of Residual Powder and Water Extraction Protein on the Surface of Medical Gloves" Requirements.
(3) Residual ethylene oxide when sterilized with ethylene oxide
It shall meet the relevant requirements in GB / T 16886.7-2001 "Ethylene Oxide Sterilization Residues in Biological Evaluation of Medical Devices, Part 7"; if there are endotoxin requirements, it shall also comply with YY / T 0616-2007 "Single use Medical gloves biological evaluation requirements and tests.

2020年5月6日星期三

Common Sense and Misunderstanding of Wearing Medical Latex Gloves

1. Indications for the use of surgical gloves: surgical interventional radiation intervention, central venous catheterization, indwelling catheterization, total parenteral nutrition and preparation of chemotherapy drugs.
2. Indications for the use of inspection gloves: when in contact with the patient's blood, body fluids, secretions and items contaminated with body fluids, such as: intravenous injection, intravenous catheter extubation, inspection, processing equipment, waste disposal, etc.
Medical latex is white latex extracted from rubber tree or leached with rubber particles. It is used to produce medical latex products. Rubber particles, ie 33% polyisoprene, have a particle size of approximately 0.3 m and can be maintained on the particle surface by protein and soap. After adding the vulcanizing agent, medical gloves are prepared by dipping, medical latex tubes are prepared by extrusion, and other medical products are prepared by casting. The formulated medical products meet the medical standards of the corresponding products.
Our company is a machinery manufacturer that mainly researches, develops, designs and produces high-quality latex gloves equipment and finished products. It mainly produces: latex gloves production line china, nitrile gloves production line china, packing machine, pvc gloves equipment, stripping machine and a series of processing equipment. for many years, Fengwang Mining Area is based on the research and development and manufacturing of cutting-edge equipment technology, and provides customers with machinery and equipment services for the entire plant. The difference is that our corporate culture is to become true friends with customers. The difficulties our customers encounter in the process of production and factory establishment are also our difficulties. We will stand with our customers and work together to find solutions.
Fengwang is based on the business philosophy of "aspirations to go high". Always pursuing innovation and breakthroughs, keeping pace with the times. It has a relatively high position in the industry in terms of production line process layout, equipment structure design, and material selection. The complete set of equipment for medical gloves production line is at a relatively advanced technical level in the industry. Its stability, reliability, advancedness and durability are favored by most domestic latex product manufacturers.
Stripping Machine
Stripping Machine
What is a medical glove: gloves are the standard prevention for medical personnel during work. The purpose of gloves is to prevent hands from being contaminated with microorganisms, to prevent the spread of microorganisms already on the skin or hands, and to avoid damage or reduction of chemicals. Injury of sharps.
Matters needing attention 1. Gloves should be changed between patients with different treatments. 2. After the operation is completed, take off the gloves and wash your hands according to the prescribed procedures and methods. Wearing gloves cannot replace hand washing. Hand disinfection should be performed when needed. 3. When the gloves are found damaged during operation, they should be replaced in time. 4. When wearing sterile gloves, prevent gloves from contaminating.
Hand washing and sanitary hand disinfection should follow the principles: ① When the hands are contaminated by naked eyes such as blood or other body fluids, wash hands with soap (soap) and running water; ② When there is no visible contamination of hands, use quick-dry Hand sanitizer disinfects hands instead of washing hands. The composition characteristics of medical latex products: 1. It has the advantages of high efficiency, wide spectrum, wide pH range, good chemical stability, etc. 2 Use can reduce patient's pain and burden.

How to Choose a Side Leakage Machine